CLASS B / European B Standard
Type: 3-Times Pre-Vacuum Preceding Vacuum Drying
Electric Tension: 220V/110V
Material: Stainless Steel
Capacity: 18L,23L
Model:Portable Dental Clinic Autoclave Sterilizer
Transport Package: 1PCS/CTN
Origin: China
Theory: Pressure Steam
Certification: CE, ISO
LCD Display: With LCD Display
Option Built-out type printer can be attached to record the processof sterilization.
Medical Device Regulatory Type: Type 2
Operation: Automatic
Certificate: CE, ISO
Trademark: BestDent, OEM
Specification: Class B
HS Code: 9018499000
We use import double headvacuum pump. External heating system + specialtysteam generator.
LCD display, with date and timefunction.
Water quality inspect function.
Intellective fill in water function. Bowie&Dick/Helix Test,Vacuum TestSafety valve, door locking system,temperature, several pressurecontrol protection.
The sterilization drying time is adjustable, with optimization sterilization efficiency.
Option Built-out type printer can be attached to record the processof sterilization.
It adopts European B standard, with 3-times pre-vacuum precedingvacuum drying.
Type:3-Times Pre-Vacuum Preceding Vacuum Drying
Function:for Medical & LabInstruments
Sterilization Grade:Class B
ChamberMaterial:Stainless Steel
Display:LCD Display
Fill in Water:Automatic
Minitype Printer:Be Optional
SafetyValve:Yes
Door Locking System:Yes
Temperature,Pressure Control Protection: Yes
InputVoltage: AC220~240V/50~60Hz
Power: 1900W
Cavity Size: φ 24.7× 45cm
Net Weight: 50Kg
Sterilization Temperature: 121º C/1.1bar, 134ºC/2.1bar.
Disinfection Temperature: 105º C/0.2bar.
Safety Devices:
A...Over heat control: When inner temperature is overheated, power will be shut down
Automaticlly and alarm system
B. Over pressure control: It have alarm system when over pressure.
C. Safety door lock system
D. Low water level indictor: It have alarm system when low water
Model | CLASS B 18L | T& S 23B+ | |
ChamberDimensions(mm)(Φ × D) | 250× 380 | 250× 500 | |
Chamber Capacity(liter) | 18L | 23L | |
Overall Size(cm)(L× W× H) | 48× 56× 42 | 48× 67× 42 | |
Heater | 1800W | 2000W | |
Net Weight(KGS) | 46.5 | 56 | |
Gross Weight(KGS) | 55 | 65 | |
Packing Size(cm) | 73× 60× 50 | 87× 60× 50 | |
Minimum Desk Size(cm) | 48× 40 | 48× 50 | |
Power Supply | 220± 10%, 50/60HZ, 10A | ||
Sterilize Temperature | 121/134 | ||
Sterilize Time | Please refer to different programs. | ||
Dry Procedure | Vacuum drying | ||
Sterilizer Construction | Stainless steel SUS#304 | ||
Water tank | On the top | ||
Stainless steel instrument container | 3 trays |